Télécharger Imprimer la page

Dometic FreshWell2000 Instructions De Montage page 16

Masquer les pouces Voir aussi pour FreshWell2000:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 35
Disposal
Problem
Cause
Under-bench air
No supply voltage (230 Vw)
conditioner does
connected.
not switch on.
The voltage is too low (under
200 Vw).
The voltage converter is defective.
The defective thermal protection is
defective.
The electrical fuse of the power
supply is too low.
Under-bench air
The air filter is obstructed.
conditioner stops
The voltage is too low (under
working.
200 Vw).
The voltage converter is defective.
The defective thermal protection is
defective.
The condenser fan is damaged.
The heat exchange coils are polluted.
The external blower is defective.
Under-bench air
One of the temperature sensors is
conditioner does
defective.
not switch off.
9
Disposal
Regulations for environmental safety and correct disposal
All organisations must apply a set of procedures to identify, evaluate and
control the influence that their activities (manufacturing, products, services,
etc.) have on the environment.
The procedures to be followed to identify significant environmental impact
must take the following factors into account:
 use of raw materials and natural resources
 atmospheric emissions
 discharge of liquids
 waste management and recycling
 contamination of the soil
14
FreshWell2000
Remedy
➤ Check the power supply.
➤ Contact an authorised work-
shop.
➤ Check the electrical fuse of the
power supply.
➤ Clean the air filter.
➤ Contact an authorised work-
shop.
➤ Contact an authorised work-
shop.
EN

Publicité

loading