Temperature Settings; Transport, Storage And Packaging; Transport Inspection - oventrop Regudis W-HTF Mode D'emploi

Masquer les pouces Voir aussi pour Regudis W-HTF:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

NOTICE
According to the DVGW work sheet W551,
dwelling stations are small installations if the pipe
content of each potable water pipe behind the
station does not exceed 3 litres. As a result, the
following pipe lengths for copper and stainless
steel pipes must not be exceeded:
d
[mm]
d
a
DN 10
12
DN 12
15
DN 15
18
DN 20
22
DN 25
28

2.5 Temperature settings

NOTICE
When leaving the factory, the potable water
temperature is set to approx. 60 °C (position 5 at
the temperature controller).
The system temperatures must comply with the
legal requirements.
Especially when operating a circulation system, it
must be ensured that a temperature of 55°C is not
undercut at any point of the pipework.
WARNING
High system temperatures may enhance corrosion
and the formation of calcium deposits. The
specifying engineer and the user of the system are
responsible to evaluate these factors and to take
preventive measures if required (e.g. water
treatment).
WARNING
Risk of scalding Outlet temperatures exceeding
43° C can lead to scalding.
[mm]
V/L [l/m] l
[m]
i
max
10
0.08
37.9
13
0.13
22.6
16
0.20
14.9
20
0.31
9.5
25
0.49
6.1
3 Transport, storage and
packaging

3.1 Transport inspection

Upon receipt check delivery for any damages caused
during transit.
Any damage must be reported immediately upon
receipt.
Illustr. 3.1 Extent of supply
1. Dwelling station
2. Accessories set with double nipple
3. Circulation pump with digital timer
4. Cable connection group with actuator
5. Stainless steel pipe circulation pipe
3.2 Storage
The dwelling station "Regudis W-HTF" with high
temperature circuit must only be stored under the
following conditions:
– Do not store in open air, keep dry and free from
dust.
– Do not expose to aggressive fluids or heat sources.
– Protect from direct sunlight and mechanical
agitation.
– Storage temperature: –20 °C up to +60 °C,
max. relative humidity of air: 95 %
3.3 Packaging
Packaging material is to be disposed of environmentally
friendly.
1
4
3
5
2
19

Publicité

Table des Matières
loading

Table des Matières