14. Troubleshooting
Fault
The compressor does not start.
The compressor starts but there is
no pressure.
Compressor running, pressure
shown on the display, but tools are
not running.
Possible cause
No supply voltage.
Insufficient supply voltage.
Outside temperature is too low.
Motor is overheated.
The non-return valve leaks.
The seals are damaged.
The hose connections have a
leak.
www.scheppach.com
Remedy
Check cable, power plug, fuse and socket.
Avoid extension cables that are too long.
Use extension cables with sufficient wire
cross-section.
Do not operate below +5° C outside tem-
perature.
Allow the motor to cool down. If necessary,
eliminate the cause of overheating.
Replace non-return valve.
Check seals, have broken seals replaced at
a specialist workshop.
Check compressed air hose and tools, re-
place if necessary.