5.7
Mounting with cable gland kit
Mounting to a free G1, G1
1. Route the cable of the pressure sensor trough the G1 cable gland. For
mounting to the tank, use the appropriate parts of the cable gland kit
required for your specific tank.
2. Determine the cable length as described above.
3. Tighten the cable gland so that the cable can no longer be moved and that
the connection is odour-tight.
Mounting
5. At the cable gland, adjust the
cable length of the sensor cable in
such a way that the tip of the pres-
sure sensor reaches the tank bot-
tom. The measuring hole of the
pressure sensor must not be
immersed in sludge that may be
present at the tank bottom. Any
liquid below the measuring hole of
the pressure sensor is not
detected by the pressure sensor.
6. Only fit the withdrawal hose (E)
after you have inserted the pres-
sure sensor.
7. Tighten the cable gland so that
the cable can no longer be moved
and that the connection is odour-
tight.
1
or G2 threaded socket in the tank.
/
2
EN
17
DIT 10