5.1.3
Tank height (max. liquid level)
1. Determine the tank height in mm (this information can be found in the
technical data of the tank).
Determined tank height: ___________________________________ mm
5.1.4
Current liquid level
1. Determine the current liquid level in mm (for example, use a dipstick to
determine the liquid level).
Determined liquid level: ___________________________________ mm
5.2

Mounting the wall bracket

5.3
Mounting the junction box
The enclosed moisture-proof junction box is not suitable for outdoor applica-
tions.
1. Use the outdoor junction box for outdoor applications.
2. Mount the moisture-proof junction box at a suitable location using the
enclosed screws.
- Verify that the cable length is sufficient because the control unit must be
removed from the wall bracket if you need to replace the battery.
3. Fit the control unit into the wall bracket.
4. Route the cable (pressure sensor cable and cable of the control unit) into
the moisture-proof junction box.
5. Push the cable gland required for the tank onto the cable of the pressure
sensor; verify correct orientation.
Mounting
1. Mount the wall bracket at a suita-
ble location using the enclosed
screws (4 x 30 mm).
EN
12
DIT 10