Mounting
The optimum point in time for the installation of the product is when the tank
has the maximum filling level. This achieves the highest accuracy.
If the product is not installed when the level in the tank has the maximum
value, you can correct the tank data at maximum level to further increase the
accuracy of the product.
5.1
Determining the tank data
You must determine the tank data before installing the product.
1. Document the tank data you have determined in the form below.
5.1.1
Tank shape
1. Determine the tank shape code using the table below.
Tank shape
code
1
2
3
4
5
6
Determined tank shape code: ________________________________
5.1.2
Tank volume
1. Determine the total volume of the tank system in litres (this information
can be found in the technical data of the tank).
Determined tank volume: _________________________________ litres
Mounting
Tank shape
Linear tank
Cylindrical tank
Spherical tank
Plastic battery tank
Oval tank
Plastic tank with recess Plastic tanks with larger recesses in
Description
Rectangular tanks, upright cylin-
ders, steel tanks welded in the base-
ment and all other linear measuring
applications
Vertically mounted cylinders
Spherical tank
Plastic battery type tanks with
straps or bulges
Oval basement tanks, for example,
glass-fibre reinforced tanks or sheet
metal tanks
the tank centre (manufacturers: for
example, Roth, Werit)