10. Configuration

A local connection is required to configure the unit for the first time. Once this first configuration has been carried
out, a remote connection can also be established. The processes for each case are described below.
The configuration is done through the INGEREV WEB Manager application.

10.1. Local connection

To establish a local connection the charger and computer must be connected to the same communication network.
The local connection can be done through an Ethernet or Wi-Fi network.

10.1.1. Local connection via Ethernet

CAUTION
The Ethernet cabling must be category 5E or higher.
To make the connection, follow these steps:
1.
Connect the computer to the unit using one of the available Ethernet connectors (J17 or J18).
J18
2.
On the laptop computer, open the web browser and open http://serialNumber.local:8080, where
serialNumber corresponds to the unit's serial number (for example, http://6S0A182A0001.local:8080).
The serial number is the unit's unique identification and is located on the specifications plate.
3.
Enter the username and password. The username and password are specified on the documentation
delivered with the unit.
38
J17
ABW2011IQM01_D - Installation and Operation Manual