Specification Table - Ingeteam INGEREV FUSION Série Manuel D'installation Et Usage

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 93
Ingeteam

2.3. Specification table

AC inputs and outputs
Voltage
Maximum input power
Frequency
Maximum input current
Output connectors
Connection mode
Regulations and safety
Standard regulations
Overcurrent
Indirect contacts
Overvoltage
(1)
Functionalities and accessories
Communications
Communication protocols
HMI
General information
Stand-by consumption
Energy measurement
Operating temperature
Humidity
Maximum altitude
Weight
Dimensions (height x width x depth)
Enclosure
Protection class
Pollution degree
Markings
Directives
Manual or resettable protection depending on model
(1)
(2)
Type B alternative exists
12
INGEREV FUSION Street
Single phase
Three phase
(FS1)
(FS3)
1 ph. + N +PE
3ph. + N +PE
230 Vac ± 15%
400 Vac ± 15%
14.8 kW
44 kW
(7.4 kW + 7.4 kW)
(22 kW + 22 kW)
Configurable (type 1 and type 2 both in socket and in cable, Type 3A, CEE 7/3 Type F, CEE
5 socket types and 2 cable types
IEC-61851-1, IEC-61851-21-2, IEC-61000
Overcurrent protection device (Curve C)
Residual current device (RCD) 30 mA Type A
Overvoltage protection Type III
Ethernet, Wi-Fi, Ethernet Switch
4.3" TFT color display, RFID (Mifare Classic 1K&4K, MifareDesFire WV1, NFC)
33 kg (2 x Type 2)
1400 x 320 x 215 mm
IP54  / IK10 (IK08 display)
Low Voltage Directive: 2014/35/EU
EMC Directive: 2014/30/EU
ABW2011IQM01_D - Installation and Operation Manual
INGEREV FUSION Wall
Single phase
(FW1)
1 ph. + N +PE
230 Vac ± 15%
14.8 kW
(7.4 kW + 7.4 kW)
50 / 60 Hz
64 A (32 A + 32 A)
7/5 Type E)
/ DC leak detector (optional)
(1)
GPRS-3G/4G (optional)
OCPP
< 10 W
2 x MID Wattmeters
-25 ºC to 50 ºC
<95%
2000 m
24 kg (2 x Type 2)
800 x 320 x 215 mm
Galvanized steel
PD3
CE
Unit description
Three phase
(FW3)
3ph. + N +PE
400 Vac ± 15%
44 kW
(22 kW + 22 kW)

Publicité