Operating Elements And Displays On Device; Drive - Titan PowrPlast 1000 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

PowrPlast 1000
4.1
OPERATING ELEMENTS AND DISPLAYS ON
DEVICE
1
Delivery volume controller 0-10
2
Selector switch for operating mode
3
Indicator light (Error)
4
Operating light (Power)
5
EMERGENCY STOP switch
POWER ERROR
4
3
5
2
The delivery volume controller (Fig. 3, 1) is used to regulate
the convey capacity from 0-10 smoothly.
The remote control (available separately, art.
no. 2308 417) can be used to conveniently
control the pump's delivery volume from the
spray lance.
The selector switch (Fig. 3, 2) o ers the following modes:
"A" position = automatic
Basic setting for control with an automatic
A
spray lance, pneumatic spray lance or re-
mote control
"F" position = manual activation
Switches on the mortar spraying machine.
A
This setting is required for:
• disassembling the pump unit
When using the pneumatic lance, this set-
ting is also needed for:
• pre-rinsing the mortar hose to improve
the material's ability to slide
• cleaning
"R" position = reverse gear (must be held in
this position).
A
This setting is required for:
• relieving pressure on the mortar hose
• assembling the pump unit
SPEED
1
Detailed explanation of selector switch use:
If the selector switch is in the "A" position, the PowrPlast 1000
can be switched on and o with the material shut-o on the
automatic or pneumatic spray lance.
If there is no spray lance fitted (e.g.: assembly/disassembly the
pump unit ), the machine is switched on using the "F" switch
position and o using the "A" position.
Since the air supply through the compressor needs to be
switched o to clean the mortar hose, the pneumatic lance
is not controlled using the material shut-o . In this case, the
machine must therefore also be switched on using the "F" po-
sition.
Important: control via the selector switch and
material shut-off are treated equally.
The machine can be switched from the "A" po-
sition (control using material shut-o ) to "F" at
any time.
We would therefore recommend that only one
person operate the machine.
The operating light (green, Fig. 3, 4) indicates that the machine
is energised and ready.
The indicator light (red, Fig. 3, 3) indicates a fault. For detailed
information about this kind of fault, refer to the „Recti cation
of faults" section on page 44.
If the selector switch is in the "F" position when
the mains plug is plugged in, the machine will not
switch on.
Briefly move selector switch to "A" and then back
to "F" to switch on the machine.
EMERGENCY STOP switch
When the EMERGENCY STOP switch is pressed, the PowrPlast
1000 is switched off immediately.
Turn the EMERGENCY STOP switch in order to release it again.
The machine remains switched o after release. To switch it on
again, the selector switch must be briefly set to "A" and then
to "F".
4.2

DRIVE

When an overload occurs, the mortar spraying machine
switches off automatically (red indicator light lights up).
Move selector switch (Fig. 3, 2) to "A" and disconnect mains
plug. Set delivery volume controller (Fig. 3, 1) to „ 0".
Wait around 5 minutes, then plug the mortar spraying machine
back in and switch on. Set the delivery volume required.
The drive unit heats up during operation. This
is normal and not a sign of malfunction.
GB