4 0 m m
2 0 m m
Tensioning strip from the transport pallet

Electrical connection

All electrical work must be performed by a qualified service techni-
cian in accordance with all applicable codes and standards.
- The electrical connection and wiring diagram are located behind the
mounting flap of the right side column.
- The values for the electrical connection and fuse rating can be
found on the data plate (see the "Technical data" chapter in this
document).
- If the appliance is hard wired, a multiple-pole separator must be in-
stalled. Separators with a contact gap of more than ⅛" (3 mm) are
valid as separators. All components have to bear CSA or UL ap-
proval.
- The plug connection or the disconnector must be accessible at all
times.
- You must be able to lock the disconnector or monitor the point of
disconnection at all times in case the appliance has to be discon-
nected from the power supply.

Duct for venting steam

 Never connect an exhaust hood to an active chimney, dryer
vent, flue, or room venting ductwork It must also be laid separately
to any exhaust air duct used for a laundry dryer.
The moist warm exhaust air must be vented to the outdoors by the
shortest route possible. To ensure optimum air flow, the ducting
should contain as few bends as possible and airtight connections. Fil-
ters and louvers may not be installed into the exhaust duct.
Since the relative humidity can amount to up to 100 %, suitable mea-
sures must be taken to prevent condensate from flowing back into
the machine. If the available pressure of the machine fan for over-
coming conductor resistance does not suffice, an according dimen-
en - Installation and planning notes