2.6.1 - STATUS 1 rest page

On switching on of the equipment after display of the welcome page, or when NEXT is
displayed if the displayed page is the value page, this page is displayed.
The following states are permanently displayed:
• Panel number assigned on panel setting up (refer to Installation chapter of this manual).
• Detail value directly modifiable via ADJUST control.
• Iris aperture
The following states are conditionally displayed:
• Effect filter value if other than Clear.
• Density filter value if other than Clear.
• Stepped Gain value if other than 0 dB.
• Shutter or Clear Scan value if either is in use.
• Fine Iris Range and Sensitivity value if this function is in use.
• 1/2 indication if a second status page exists.
Density filter
Effect filter
Detail value
Detail Adjust with ADJUST

2.6.2 - STATUS 2 rest page

By pressing the NEXT key, this page is displayed if the 1/2 indication is displayed in the
STATUS 1 page.
The following states are conditionally displayed:
• KNEE to OFF.
• KNEE to AUTOHOLD.
• ABL to ON.
• GAMMA value, if other than 0.45.
• DFZ to ON.
• SKIN DTL 1 or (and) 2 to ON.
• SOFT DTL to OFF.
• BLACK STRETCH to ON.
THOMSON OCP 42/OCP 50
User manual
Chapter 2 -OCP 42/OCP 50 Operating Instructions
ND 1 6
S T A R
X X
D E T A I L
Control
Presence of
2nd status page
Figure 2 : Rest STATUS 1 page
Description of rest pages
Gain
Panel No.
3 d B
6
Clear Scan or Shutter
C L C S 2 0 1 . 2
±
F I N E F X X .
X F
FINE IRIS
1 / 2
F X . X
Iris
B1500M24LA
September 2000