Power Supply; Tools And Materials Required - GE Monogram ZV30H Instructions D'installation

Masquer les pouces Voir aussi pour Monogram ZV30H:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

POWER SUPPLY

IMPORTANT – (Please read carefully)
WARNING:
FOR PERSONAL SAFETY, THIS APPLIANCE MUST
BE PROPERLY GROUNDED.
Remove house fuse or open circuit breaker before
beginning installation.
Do not use an extension cord or adapter plug with
this appliance. Follow National Electrical Code or
prevailing local codes and ordinances.
Electrical supply
This vent hood must be supplied with 120V, 60Hz,
and connected to an individual, properly grounded
branch circuit, and protected by a 15- or 20-amp
circuit breaker or time-delay fuse.
• Wiring must be 2-wire with ground.
• If the electrical supply does not meet the above
requirements, call a licensed electrician before
proceeding.
• Route house wiring as close to the installation
location as possible. Wiring can enter from the
ceiling or rear wall. Route additional length from
the ceiling or wall to reach the junction box.
• Connect the wiring to the house wiring in accor-
dance with local codes.
Grounding instructions
The grounding conductor must be connected to
a ground metal, permanent wiring system, or an
equipment-grounding terminal or lead on the hood.
WARNING:
of the equipment-grounding conductor can result
in a risk of electric shock. Check with a qualified
electrician or service representative if you are in
doubt whether the appliance is properly grounded.
Installation Preparation
The improper connection

TOOLS AND MATERIALS REQUIRED

(NOT SUPPLIED)
Pencil and tape measure
Spirit level
Phillips screwdriver
Electric drill or cordless driver
with #2 Phillips bit, 1/8", 5/16"
and wood-cutting hole saw
drill bits
Stepladder
UL-listed wire nuts
Wire Nuts
Aluminized
Strain relief for
duct tape
junction box
Strain Relief I
6
Safety glasses
Gloves
Hammer
Flashlight
Utility Knife
Metal snips
Pliers
Masking
Wire cutter/stripper
tape
Saber saw or Key Hole saw
8" round metal
duct, length to
suit installation
120V 60Hz. 15- or 20-Amp,
2-wire with ground, properly
grounded branch circuit

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Monogram zv30hsrss

Table des Matières