4.5 Cable entry

The product is supplied with plastic caps for
cable entry protection. They cannot be used for
installation.
Unused cable entries must be closed using
appropriate Ex certified locking devices with "db"
and "tb" explosion protection, suitable for the use
conditions and installed correctly.
All cable glands shall be Ex certified, as appropriate,
with protection type "db" and "tb", suitable for the
conditions of use and installed correctly.
When conduit is used, a suitable Ex certified
stopping box shall be used, as appropriate, with
protection type "db" and "tb", suitable for the
conditions of use and installed correctly.
The stopping box must be fitted within 50mm
(1.97in) from the enclosure entry.
The cable entry temperatures are specified in the
marking.
To maintain the IP level of product use cable glands
with appropriate IP level and apply to threads a
sealant compliant with standard IEC/EN60079-14.
MNVCMPXHDC_2222_EN

4.5.1 Stopping plug

The stopping plug supplied is not KCs
certified.
With the product, an Ex certified stopping plug
is supplied with "db" and "tb" explosion-proof
type protection. Thread sealant is also supplied, in
compliance with IEC/EN60079-14, the use ensure the
IP degree.
The stopping plug installation instructions are
available on https://peppers.co.uk.
Fig. 1
11