6. Service

6.1. General

All maintenance activities must happen at an disconnected machine and hoses without pressure.
Checking the electric components can happen exclusively by an expert. Exclusively accessories and replace-
ment components which have been approved by the manufacturer can be used. Directly after the activities all
securities- and protection parts must be assembled, before the machine is put in functioning; "a golden rule" that
contributes to a perfectly working machine with few problems, is well the following:
A DAILY CONTROL AND CLEANING OF THE MACHINE FREQUENTLY DO WONDERS!
To be able to guarantee a perfectly working system, one has first necessary a reliable and technical well consid-
ered machine, which is then faced secondly at regular times with a thorough maintenance.
Therefore the experience and the "know-how" of DiBO a technical good working machine is insured and large
maintenance turns can be carried out by experienced DiBO technicians by means of appointment or maintenance
contract, we can suppose in advance that it is satisfied to these two points.

6.2. Maintenance diagram

6.2.1 General
The user can carry out only those actions for which in this book authorisation are given.
Each other act has been prohibited! Check even all transmission belts on good tension and possible defects.
If this case is not, then best consult the proper maintenance technicians.
PAY ATTENTION: Take care that the transmission belts are not in movement and observe the applying safety
standards!

6.2.2. Periodic maintenance

- Control of the electric cables, high and low pressure hoses and cou-
- All following refreshments of pump oil and service on the cleaner.
- Extra control/replacement of joints, valves, o- rings by acknowledged

6.2.3. Control of oil level / refreshing of pump oil

Check for each use of the machine the oil by way off oil level glass or with the oil level bar.
Oil must stand right with the sign of the oil level bar, if the this case is not, oil tops up until the sign.
If oil looks forward to there milky, consult directly the DiBO technicians. To refresh oil, as follows work goes:
- Unbolt the drain plug below the pump.
- Unbolt the tap with the oil level bar.
- Catch all oil in a barge and remove oil.
- Force up the drain plug there and top up the oil in the breach to the upper part to the right level.
- Force up the tap with the oil level bar there. Recommended oil: 1.836.042.
Replace pump oil at ECN- L: check the oil level on weekly basis.
If necessary add the missing oil through the oil plug pos.1. Check oil level (through the oil looking glass, pos.
2) when the pump is at room temperature. When changing the oil (removing plug pos.3), the pump should be
at its working temperature, remove the dirty oil (catch in a barge and remove environmental friendly). Bolt the
removing plug 3 again after the dirty oil is removed.
Open the oil plug (pos. 1) again and fill/refresh with new oil.
6.2.4. Cleaning of the water filters
Clean the water filters regular and remove possible dirt.
ECN-M/T/L : REV 0
pling and control of the oil level.
- Refreshing pump oil.
- Cleaning water filter.
DiBO- technicians.
After each use.
First 50 hours.
Each 50 hours/every month.
Each 400 hours/yearly.
Each 600 hours.
DiBO n.v. 55