Troubleshooting
Error message E0
Error message E1
Error messages E2 to E7
Fill level display in water
boiler is difficult to read:
The appliance does not heat
up.
Steam rising from housing. Seals are calcified.
The hair steamer P71 is drip-
ping, the ST5 tripod is wet /
the condensate trap over-
flows during treatment.
11. Troubleshooting
You can apply the following potential solutions yourself, taking into considera-
tion the safety instructions.
Error messages appear in the display. At the same time, a beeper function is ac-
tivated. A distinction is made between appliance errors and operator errors.
Water boiler not inserted, calcified or
defective.
No water in water boiler.
Appliance defective!
Warm-up phase takes longer than
180 seconds.
Water boiler is calcified.
Seals are calcified or defective.
Appliance defective!
Water boiler is calcified.
Water boiler is inserted incorrectly.
Water boiler is calcified or defective. Descale or replace the water boiler.
Cover is open.
Water boiler connection is defective! Switch off appliance and pull out mains plug. Notify
Seals are defective!
Seals are missing.
Water boiler is defective!
Condensate trap is incorrectly insert-
ed or full.
Water boiler is defective!
The oval seal is calcified, defective or
missing.
Insert, descale or replace water boiler.
Fill the water boiler. It may take some minutes for the
error message E0 to disappear.
Switch off appliance and pull out mains plug. Notify
Customer Service.
Fill with hot water.
Descale the water boiler.
Clean or replace the seals.
Switch off appliance and pull out mains plug. Notify
Customer Service.
Descale the water boiler.
Check the position of the water boiler in the appli-
ance.
Close the cover.
Customer Service.
Clean the seals.
Replace the seals.
Insert the seals.
Replace the water boiler.
Check the position of the condensate trap in the ap-
pliance or empty it.
Replace the water boiler.
Descale or replace the oval seal.