the electronic motor and electronic control, pipetting is easy and comfortable, yet still fast and
accurate. It operates on the air displacement principle (i.e., an air interface) and uses detachable,
disposable tips, which are easy to remove with a soft touch tip ejector.
The adjustable, index finger-operated pipetting trigger uses natural hand movement. The Hach
TenSette plus provides many functions that are very practical for daily use in laboratory work, such
as forward, reverse and repetitive pipetting, stepper and diluting modes.
The adjusted delivery volume is clearly indicated in the LCD display on top of the handle. The long
lasting lithium ion battery is always charged with rapid charge technique.
All pipettes are factory calibrated. A Pipette Inspection Report, which covers calibration conditions
and results, is delivered with the pipette.

Product components

Make sure that all components have been received. If any items are missing or damaged, contact the
manufacturer or a sales representative immediately.
• Hach TenSette plus (supplied with installed rechargeable battery, Item no. BBP089)
• Charger (includes external power supply 100–240 V, 50/60 Hz, 15 mmA and power plug adapters
for EU, UK, US, Australia)
• Shelf hanger
• Spare O-ring and tube of grease
• Sample Hach pipette tips

Installation

Multiple hazards. Only qualified personnel must conduct the tasks described in this section of the
document.

Connect to power

Explosion and fire hazard. Battery substitution is not permitted. Use only batteries that are supplied by
the instrument manufacturer.
Fire and explosion hazard. Lithium batteries may get hot, explode or ignite and cause serious injury if
exposed to abuse conditions.
Use only the original Hach TenSette plus charger and battery.
The pipette battery must be charged before initial use. You can use the pipette while the charger is
connected. The charging time is typically less than one hour. An indicator in the LCD display shows
the charge level of the battery. When the indicator shows an empty battery, pipetting is not possible,
and the pipette must be charged again.
1. Connect the lead of charger to the socket on the back of the pipette.
2. Connect the charger to an AC wall socket.
Note: If the battery is completely empty, it may take a few minutes before the pipette will turn on.