Technical data

Input starting battery
Nominal battery voltage
Recommended battery capacity
Max. power consumption
Current consumption
• Max. current consumption
• Current consumption in standby mode
• Current consumption OFF
Input over-voltage cutoff (EURO 6+)
Charging output house battery
Nominal battery voltage
Recommended battery capacity
Charging current (I phase)
Charging/buffer/load current, regulated
(U1, U2 phase)
Minimum battery voltage for start of
charging
Maximum pre-charge current of a deeply
discharged battery (<8 V)
Reset voltage (U2 to U1, 30 s)
Limitation of charging voltage
External over-voltage cutoff (20 s)
Reverse current from battery, OFF
Voltage ripple
General technical data
Protection class/ type
Ambient temperature for operation
Ambient humidity
Dimensions (W x D x H)
Weight
Inspection/certification
26
MT LB 30
12 Vg
60 Ah/ 70 Ah
480 W/ 540 W
37 A/ 44 A
0.07 A
0.0004 A
16.5 V
12 – 13.3 Vg
50 – 200 Ah/
60 – 240 Ah
25 A/ 30 A
0 A – 25 A/ 0 A – 30 A
0 V
12.5 A/ 15 A
12.75 V
15 V
15.5 V
0.000 A
< 50 mV rms
270 x 223 x 74 mm (fig. g, page 11)
2.75 kg
4445103799
MT LB 2412-25
24 Vg
50 Ah
450 W
18 A
0.09 A
0.0004 A
32.2 V
12 – 13.3 Vg
50 – 200 Ah
25 A
0 A – 25 A
0 V
22.5 A
12.75 V
15 V
15.5 V
0.000 A
< 50 mV rms
I/IP21
–20 °C to +45 °C
≤ 95 %, non-condensing
2.8 kg
MT LB 2412-45
24 Vg
60 Ah
740 W
30 A
0.11 A
0.0005 A
32.2 V
12 – 13.3 Vg
90 – 360 Ah
45 A
0 A – 45 A
0 V
12.5 A
12.75 V
15 V
15.5 V
0.000 A
< 50 mV rms
2.95 kg

Publicité

loading

Ce manuel est également adapté pour:

Buttner mt lb2412-25Buttner mt lb 2412-45