Displays
No. in
fig. 3,
Description
page 4
6
AC supply
7
Constant output
8
Operating hours
9
DC voltage
10
Messages
8

Operating the generator

A
NOTICE!
Do not run the generator over 70 % of the maximum constant output for
the first 50 operating hours (run-in phase).
I
NOTE
Run the generator at a maximum of approx. 75 % of the maximum
continuous load after the run-in phase.
By doing this you can prolong the service life of the generator and
maximise its efficiency.
8.1
Basic notes on operation
!
CAUTION! Beware of injury
Do not insert your fingers or objects into the air nozzles or the intake
grille.
Please note the following basic information:
• Always check the oil level before use (chapter "Checking the oil level" on
page 21).
• TEC29 EV LPG only: Check there are no leaks from the gas supply using a leak
detection spray before every use.
• Even small overloads in the long-run will cause the cut-out switch (TEC29 EV) or
the fuses (TEC29 EV LPG) to trigger.
EN
Operating the generator
Actual voltage output
Current capacity of connected consumer
Time the generator is in operation
Battery voltage
Status reports of the generator (see chapter
"Display messages" on page 19)
17