Connecting The Electrical Power To The Generator - Dometic TEC29 Instructions De Montage

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 49
TEC29, TEC29LPG
10
Connecting the electrical power to the
generator
D
DANGER! Danger of electrocution
Make sure there is no voltage at electrically operated components
before carrying out work on them!
I
NOTE
Observe the applicable guidelines in the country of the consumer.
10.1
Important notes on the electrical connection
 Only a qualified electrician should connect the generator to the electrical
power.
 Check that the voltage specification on the type plate is the same as that
of the power supply.
 Do not lay the 230 Vw mains cable and the 12 Vg cable together in the
same cable duct.
 Do not lay cables which are loose or bent next to electrically conductive
material (metal).
 Connect the generator to a power circuit which can supply the necessary
current (see chapter "Technical data" on page 30).
 Select the cross-section of the cable as follows:
– 230 V: 2.5 mm²
– 12 V battery charger: 2.5 mm²
– Battery connection (length < 6 m): 10 mm²
– Battery connection (length > 6 m): 16 mm²
 Install a manual main switch which can disconnect all the consumers from
the generator with the exception of the battery.
EN

Connecting the electrical power to the generator

23

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Tec 29lpg

Table des Matières