Connecting The Remote Control - Dometic TEC29 Instructions De Montage

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 49
TEC29, TEC29LPG
➤ Connect the black wire to a suitable switch and connect the switch to the
ignition.
➤ Connect the white wire to terminal 5 of the 6-pin plug on the extension
cable.
➤ Connect the white wire to a suitable switch.
10.7
Creating a priority circuit
You can create a priority circuit using the AG 102 changeover relay whereby
the external voltage supply has priority over the generator, see circuit dia-
gram (fig. i, page 12):
Item
Description
1
230 V external voltage supply
2
Vehicle electrical distribution system
3
Connection box
➤ Mount the AG 102 changeover relay in a suitable position.
➤ Disconnect the cable which links the mains input with the circuit breaker
in the electrical distribution system of the vehicle so that the connections
can be made as shown in the circuit diagram.
➤ Use a flat plug for connecting the cable to the switch.
➤ Connect A with plug-in sleeve 4 and B with plug-in sleeve 6.
➤ Connect the cable from the 230 V connection terminal of the generator to
plug-in sleeve 1 and plug-in sleeve 3.
10.8

Connecting the remote control

➤ Connect the remote control to the connection box of the generator using
the extension cable provided on the plug for the remote control (for
TEC29: fig. e 3, page 10, for TEC29LPG: fig. f 4, page 10).
10.9
TEC29 only: connecting the float
➤ Connect the float from the tank to the float connection (fig. e 4,
page 10).
EN
Connecting the electrical power to the generator
29

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Tec 29lpg

Table des Matières