Hepa Filter Replacement - Nilfisk S2 L Manuel D'instructions

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

S2 / S3
Replacing a primary filter with manual filter shaker
1.
Manual filter shaker knob
2.
Vacuuming unit
3.
Locking lever
4.
Filter cage
5.
Filter shaker housing
Reassemble with care to avoid trapping your hands
between the vacuum unit and the container. Use
gloves that provide protection against mechanical
risks (EN 388) with a level of protection CAT. II.
After having replaced and fitted the filter in the cage,
insert filter shaker cage (4) in the shaped seat (5) of the
filter shaker.
Position the manual filter shaker knob (1) in the middle.
Reassemble vacuum unit (2) complete with cage and
filter, in the vacuum container.
Check the filter shaker works properly and if necessary
adjust the position of the filter cage by turning the
vacuum unit.
Use locking lever (3) to lock the vacuum unit in place.
If necessary contact the manufacturer's Service Centre.
GB
C343
Figure 15
WARNING!

HEPA filter replacement

Version for dust harmful for the health: Class H
Take care not to raise dust when this operation is
carried out. Wear a P3 mask and other protective
clothing plus protective gloves (DPI) suited to the
hazardous nature of the dust collected, refer to the
laws in force.
Do not use the Class H filter again after having
removed it from the vacuum cleaner.
1.
Vacuuming unit
2.
Locking lever
3.
Safety bolt
4.
Absolute filter lock ring
5.
Absolute filter disc
6.
Absolute filter
Reassemble with care to avoid trapping your hands
between the vacuum unit and the container. Use
gloves that provide protection against mechanical
risks (EN 388) with a level of protection CAT. II.
Before proceeding with these operations, turn the vacuum
cleaner off and disconnect the plug from the power socket.
Unlock the safety bolt (3).
Use lever (2) to release vacuum unit (1) then pull it up
and out of the vacuum cleaner.
Unscrew ring (4).
Pull out disc (5) and absolute filter (6).
Place absolute filter (6) in a plastic bag, close the bag
hermetically and dispose of the filter in accordance with
the laws in force.
Insert a new filter (6) with the same filtering
characteristics as the removed one.
Lock the absolute filter with disc (5) and tighten ring (4).
Replace vacuum unit (1).
Fix the vacuum unit in place with lever (2) and lock safety
bolt (3) again.