8.1 Mains connection
• The compressor can be connected to any 220 -
240-240 V~ 50 Hz shock-proof socket which is pro-
tected by a 16 A fuse.
• Before you use the machine, make sure that the
mains voltage is the same as the operating voltage
(see the rating plate).
• Long supply cables, extensions, cable reels etc.
cause a drop in voltage and can impede motor
start-up.
• At low temperatures below +5°C, sluggishness
may make starting difficult or impossible.
8.2 ON/OFF switch (fig. 1)
• To switch on the compressor, press the button (2)
on position I.
• To switch off the compressor, press the button (2)
on position 0.
8.3 Establishing connections (fig. 3, 4)
m Attention! Switch the device off for this.
When doing so, hold the coupling firmly in order to
avoid injuries due to the hose springing back.
• Connect the fitting of your compressed air tool to
the compressed air hose (5) of the compressor.
• To disconnect this coupling again, pull the quick-
coupling (4) back at the compressed air hose (5).
8.4 Using the tyre inflation device (fig. 6, 7, 8)
The compressed air tyre inflation device (G) is used
to inflate car tyres. With the corresponding accesso-
ries it can also be used to inflate and regulate bicycle
tyres, inflatable dinghies, air mattresses, balls etc.
Pressure can be released by actuating the vent valve
(7).
m Attention! The manometer has not been officially
calibrated! After inflating, please check the air pres-
sure with a calibrated device.
8.5 Using an air blow gun
You can also use the tyre inflation device (G) as an
air blow gun to clean out cavities and to clean soiled
surfaces and work equipment.
To do so, please first remove the hose with the valve
adapter (8).
Now screw the blow-out adapter (D) to the tyre infla-
tion device (G).
8.6 Using the adapter set
The adapter set enables you to use the following ad-
ditional capabilities of the tyre inflation device:
• Pumping up balls with the help of the ball needle
(F).
• The valve adapter (E) enables bicycle tyres to be
inflated.
• Filling pools, air mattresses or boats with the help
of the additional adapter (K).
 www.scheppach.com /  service@scheppach.com /  +(49)-08223-4002-99 /  +(49)-08223-4002-58
• Filling items with threaded valves (e.g. Boats) with
the screw-in valve adapter (J).
• Deflating large volume items. The deflating adapter
(C) can be used for this.
• The two conical universal adapters (A/B) can like-
wise be used for inflating air mattresses.

9. Electrical connection

The electrical motor installed is connected and
ready for operation. The connection complies
with the applicable VDE and DIN provisions.
The customer's mains connection as well as
the extension cable used must also comply with
these regulations.
When working with spray attachments and during
temporary use outdoors, the device must be
connected to a residual current circuit breaker with a
trigger current of 30 mA or less.
Damaged electrical connection cable
The insulation on electrical connection cables is of-
ten damaged.
This may have the following causes:
• Passage points, where connection cables are
passed through windows or doors.
• Kinks where the connection cable has been im-
properly fastened or routed.
• Places where the connection cables have been cut
due to being driven over.
• Insulation damage due to being ripped out of the
wall outlet.
• Cracks due to the insulation ageing.
Such damaged electrical connection cables must not
be used and are life-threatening due to the insula-
tion damage.
Check the electrical connection cables for damage
regularly. Make sure that the connection cable does
not hang on the power network during the inspection.
Electrical connection cables must comply with the
applicable VDE and DIN provisions. Only use con-
nection cables with the marking „H05VV-F".
The printing of the type designation on the connec-
tion cable is mandatory.
AC motor
• The mains voltage must be 220 - 240 V~
• Extension cables up to 25 m long must have a
cross-section of 1.5 mm
.
2
Connections and repairs of electrical equipment may
only be carried out by an electrician.