Reset The Protections - Ingeteam INGEREV CITY Ground Manuel D'installation Et Usage

Masquer les pouces Voir aussi pour INGEREV CITY Ground:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Troubleshooting
Maximum permitted charge current (error code 0512)
Description
The vehicle has not respected the maximum charge current allowed during a maximum established time.
Solution
The alarm will disappear upon completion of the charge session of the electric vehicle causing the alarm.
Communication failure with the power manager (error code 1024)
Description
Failure in the communication between the station and power manager. This error appears if the station is
configured to work together with a power manager, but it is not present.
Solution
Check the communication between the station and power manager. If there is no power manager, disable it in the
station's configuration.
The keypad does not work
Description
The charging station keypad does not respond.
Solution
Make sure that the keypad cable is correctly inserted inside the unit and that there are no loose or incorrectly
inserted cables in the control card.
If the error persists, contact the telephone support service.

12.2. Reset the protections

In the following figures we display the location of the charging stations protections to proceed to reset them after a
trip.
INGEREV CITY Ground
ABA2020IQM01_B - Installation and Operation Manual
Ingeteam
EN
ES
FR
IT
53

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ingerev city duo

Table des Matières