Ingeteam

8.1.2. INGEREV CITY Duo

Follow the instructions below to complete the local connection:
1.
Connect the communication ring.
First station
The JP1 jumper for control cards comes uninstalled. In all intermediate stations, the communication
ring must remain uninstalled, but must be installed in the two ends.
2.
To install the JP1 jumper in the end stations, access its control card. On these stations uninstall the six
bolts indicated in the following figure and remove the front.
36
Intermediate station
ABA2020IQM01_B - Installation and Operation Manual
Communication accessories
Final station