Install JP1 jumper on the control card of the end charging stations.
J P 1
Jumper JP1 uninstalled (intermediate stations)
4.
Use a USB to RS-485 converter with RJ45 connector (not supplied with the charging station) to connect
the computer to the first station of the communication ring (white cable in the following figure).
ABA2020IQM01_B - Installation and Operation Manual
J P 1
Jumper JP1 installed (stations at the two ends)