1.4 PROTECTION OF CLOSURE DEVICES

For the correct functioning of the closure devices and the long service, it is recommended to use the following
protections.

1.4.1 POWER 12 Vcc

?? STANDARD ELECTROLOCK (A emission)
?? ELECTROLOCK FOR CURRENT BREAKER
?? ELECTROMAGNET
?? RELAY (INTERFACE) DIFFERENT FROM MODEL: ref. 4092
IT IS ESSENTIAL TO CONNECT A DIODE 1N4007
(DELIVERED WITH THE CENTRAL)
TO THE TERMINALS OF EACH DEVICE RESPECTING
THE POLARITIES (See sketch)

1.4.2 POWER 12 Vca

?? STANDARD ELECTROLOCK (A EMISSION)
?? RELAY (INTERFACE) DIFFERENT FROM MODEL:
IT IS ESSENTIAL TO CONNECT A VARISTOR V68ZA2
(CONSULT) TO THE TERMINALS OF EACH DEVICE (See sketch)
_
12Vcc
+
~
~
10
ÉQUIVALENCE 1n4007
CATHODE
12Vca