Image Modalities; System Software - Nikon Optos California P200DTx rg Manuel D'utilisation

Ophtalmoscope panoramique
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Chapter 2 - Introduction
Note
The device also includes a user guide, power cable and Cat 6 cable not shown on this diagram.
A table may also be supplied.

2.6.2 Image modalities

Optos multi-modal ultra-widefield retinal imaging enables the capture of posterior images, with a field of view of
up to 200 degrees in a single capture, and in an imaging time of less than 0.4 seconds.
Depending on the configuration of your device the following image modalities may be available:
opto map
opto map is an ultra-widefield (
opto map combines sensory and choroidal reflectance images and provides UWF image views from a single
capture action:
opto map color view – an UWF color fundus image combining red and green reflectance images.
l
opto map sensory view – an UWF green laser reflectance image of the surface retina.
l
opto map choroidal view – an UWF red laser reflectance image of the deeper retina.
l
opto map
af
opto map
af
is an UWF green laser auto fluorescence image.
opto map
fa
opto map
fa
is an UWF fluorescein angiography (FA) image.
opto map
icg
opto map
icg
is an UWF indocyanine green (ICG) angiography image.
Combined opto map
fa
and opto map
Interweaved angiography is a device option that allows simultaneous capture of opto map
images. When in use, this feature alternates between opto map
capture of both studies in a single session.
opto map
plus
plus
opto map
is a higher resolution option which is available for opto map color reflectance and
l
opto map
af
modalities.
opto map
fa
and opto map
l
opto map
plus
is generally used for medical imaging. opto map is captured at a standard resolution
l
and is typically used for healthy eye exams or screening applications.

2.6.3 System software

The system contains features to help you configure the system and to capture, review, archive and retrieve
images. The system software comprises:
Scan head software that enables capture of patient studies.
l
Image server 'middleware' that encodes patient studies for storage.
l
1. Ultra-widefield images provide a field of view of up to 200° in a single capture.
Page 24 of 69
English
1
UWF
) color fundus image.
icg
imaging
icg
are captured at the opto map
fa
fa
icg
and opto map
imaging to facilitate the
plus
resolution.
Part Number: G108025/4GCA
Copyright 2017, Optos plc. All rights reserved.
and opto map
icg

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Optos california p200dtx faOptos california p200dtx icg

Table des Matières