1.4 After unpacking
Check if the delivered devices corresponds to the order.
Check the device for transport damage and completeness.
Report any defects/damage to the supplier immediately.
1.5 Place of installation
In rooms without weather exposure.
Avoid direct sunlight exposure.
Avoid dust.
Keep away from strong electromagnetic fields.
Keep away from combustible material.
Provide sufficient cooling. Install fans when installing the frequency in-
verter inside an enclosed cabinet.
Altitude of installation: ≤ 4000 m, above 1000 m with reduced power
(reduced output current).
Ingress protection rating of frequency inverter: IP20. Use of the device in
explosive atmospheres is not permitted.
The frequency inverter produces noise. For this reason it should be in-
stalled in areas where usually people do not stay for a long time.
Noise emission in operation is < 85 dB(A) in the case of sizes 1 through 7.
Noise emission in operation is approx. 86 dB(A) in the case of size 8. Use
ear protectors when staying near the frequency inverter.
1.6 Operating conditions
− Size 1...7:
Ambient temperature: 0...55°C, as from 40°C, power reduction of
o
2.5% / K should be considered.
− Size 8
Ambient temperature: -10...55°C, as from 45°C, power reduction
o
of 2.5% / K should be considered.
− Ambient pressure: 70 ... 106 kPa
− The frequency inverter may be operated in TN, TT and IT grid types.
Operation in a corner-grounded TN grid shall not be permissible.
− Environment specification: Pollution degree 2 and overvoltage category III
(IEC 60664-1) up to 2000 m installation altitude. Above 2000 m installation
altitude overvoltage category II.
− The frequency inverter may connect to power supply every 60 s. If the unit
switches on more frequently, it may be damaged. You must consider this
when operating a mains contactor in jog operation mode.