Sizes 3 and 4 ANG410 (5.5 to 15.0 kW, 400 V)
Type
ANG410
Size
Output, motor side
Recommended motor shaft power
Output current
Long-term overload current (60 s)
Short-time overload current (1 s)
Output, braking resistor
Min. braking resistance
Recommended braking resistor
(U
= 770 V)
dBC
GB
Input, mains side
Mains current
Fuses
UL type 600 VAC RK5
Mechanical
Dimensions
Weight approx.
Connection terminals
Ambient conditions
Energy dissipation (2 kHz switch-
ing frequency)
Output current (Maximum current in continuous operation)
Frequency inverter nominal power
5.5 kW
7.5 kW
1)
9.2 kW
11 kW
15 kW
1)
Connection requires a commutating choke.
2)
Mains current with relative mains impedance ≥ 1% (see „Electrical installation")
3)
Reduction of switching frequency in thermal limit range
136
2)
Quick Start Guide ANG
-19
P
kW 5.5
I
A
14.0
I
A
21.0
I
A
28.0
R
Ω
48
R
Ω
80
I
A
14.2 15.8
I
A
16
I
A
HxWxD mm
250x100x200
m
kg
A
mm
2
P
W
145
Switching frequency
2 kHz
14.0 A
18.0 A
1)
23.0 A
25.0 A
32.0 A
1)
-21
-22
-23
3
7.5
9.2
11.0
3)
18.0
22.0
25.0
26.3
30.3
37.5
33.0
33.0
50.0
48
48
32
58
48
48
1)
1)
20.0
26.0
25
20
30
250x125x200
3.0
0.2 ... 6
0.2 ... 16
200
225
240
4 kHz
8 kHz
14.0 A
14.0 A
18.0 A
1)
18.0 A
1)
3)
3)
22.7 A
22.0 A
25.0 A
25.0 A
32.0 A
1)
32.0 A
1)
-25
4
15.0
32.0
44.5
64.0
32
32
1)
28.2
35
40
3.7
310
16 kHz
9.5 A
12.2 A
3)
15.0 A
17.0 A
21.8 A
07/20