error overview
6.
During the initialization process, functionality for the main electronics components will be checked.
In case this check reveals an error, you will hear a sequence of beeps, which each represent a cer-
tain type of error, instead of the standard, high-pitched beep to indicate initialization. Please see
the following table for error allocation:
Beeps Error:
3
EEprom error
4
Error in the button
matrix
5
Line busy decoding
error
6
DTMF-tone decod-
ing error
7
1kb EEprom from
V1.30 or later
8
Microphone error
9
Microphone error
10
Microphone error
11
Microphone error
www.behnke-online.com
Manual Door intercom devices a / b Series 20 / 30 / 50
Possible causes
▸
EEprom not installed correctly in the designated base
▸
EEprom broken
▸
Either a connected button, the configuration key or the number
keypad is stuck or broken
▸
The connection cable for a button / the number keypad is broken
▸
Interference
▸
Moisture inside the circuit board or inside the connector plug
Component to decode the line busy signal is broken
Component to decode the DTMF tone dialling signal is broken
Wrong EEprom, from V1.30 only EEprom with 2 kb may be used
Compact device: the microphone connected does not maintain the
correct polarity
Universal device: the microphone connected to the integrated
MLM does not maintain the correct polarity
the microphone connected to the MLM-A of a universal device
does not maintain the correct polarity
the microphone connected to the MLM-B of a universal device
does not maintain the correct polarity
the microphone connected to the MLM-C of a universal device does
not maintain the correct polarity
GB
Error overview
62