Configuration and Set-up
Code Parameter
Reset and return to default settings:
00
* * * *
Change the security code: Default setting: 0 0 0 0
01
new security code [beep] new security code
Configuration and Set-up: Default setting: 0
02
0 = settings can be changed both directly on the device or remotely
1 = settings can only be changed remotely
Answering a call: Default setting: 1
03
0 = manually by pressing a button
1 = automatically
2 = automatically with code entry (caller protection)
3 = automatically with manual confirmation (from V1.60 or later)
Input delay for direct call buttons: Default setting: 0
04
0 = none
1 = 1 second
:
9 = 9 seconds
Connection interval: Default setting: 3
05
0 = unlimited (i.e. limited to a connection time of approx. 8 hours)
1 = limited to 1 minute
:
9 = limited to 9 minute
06
Volume Default setting: 5
0 = very low volume
:
9 = very loud volume