Configuration and Set-up
Code Parameter
Extended configurations: Default setting: 0
900
0 = disabled
1 = enabled
The following configuration may only be adjusted with enabled extended
configurations.
Amplification microphone signal (without additional power supply):
912
Default setting: 0/0
0 = 0 dB
1 = 6 dB
2 = 12 dB
3 = 18 dB
Amplification microphone signal (with additional power supply): Default
922
setting: 0/0
0 = 0 dB
1 = 6 dB
2 = 12 dB
3 = 18 dB
Divergent configurations steps for universal devices
(20-0005 / 20-0006 / 20-0018 / 20-0048)
21
Telephone number for button 1
22
Telephone number for button 2 or MLM A (yellow connector)
23
Telephone number for button 3 or MLM B (blue connector)
24
Telephone number for button 4 or MLM C (red- connector)
25
Telephone number for button 5
:
:
28
Telephone number for button 8
29
Telephone number for the button
Additional configurations steps, e.g. relay control, acoustic settings, additional electronics for
voice messages / real time clock etc. can be found in the more detailed technical manual
(www.behnke-online.de/handbuch-analog).
59
on the number keypad
Confirmation
#
#
#
#
#
#
#
#
#
#
#
#
#
#
#
:
#
#