Telecom Behnke 20 Serie Instructions page 55

Portiers téléphoniques a / b
Masquer les pouces Voir aussi pour 20 Serie:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Manual Door intercom devices a / b Series 20 / 30 / 50
GB
GB
Configuration and Set-up
Code Parameter
Relay activation interval for relay 1: Default setting: 5
09
1 = 1 second
2 = 2 seconds
:
30 = 30 seconds (up to V1.60)
:
90 = 90 seconds (from V1.61 or later)
Activation code relay 1: Default setting: 0
10
1. activation code
11
2. activation code
Activation codes consist of cyphers only and each activation code may be
up to 4 characters long.
Operation modes Relay 2: Default setting: 9
12
0 = inactive
1 = to be activated via the telephone
2 = to be activated via the number keypad
3 = to be activated via the telephone and the number keypad
4 = to be activated via the telephone & disconnecting after activation
5 = to be activated via the number keypad & disconnecting after activation
6 = to be activated via both the telephone and the keypad & disconnecting
after activation
7 = activated during outgoing calls
8 = activated during incoming calls
9 = activated during both incoming and outgoing calls
10 = activated at the beginning of an outgoing call
11 = activated at the beginning of incoming calls
12 = activated at the beginning of both outgoing and incoming calls
13 = activated while ringing
14 = activated during interference (failure in telephone line)
15 = to be activated via the emergency call control centre
16 = activated during a direct call via button 2 (from V1.20 or later)
17 = activated at the beginning of a direct call from button 2 (from V1.20 or
later)
18 = manually activated (from V1.30 or later)
19 = automated activation according to the time table (or manually, cf.
configurations step 44) (from V1.30 or later)
55
Confirmation
#
#
:
#
#
#
#
#
#
#
#
#
#
#
#
#
#
#
#
#
#
#
#
#
#
www.behnke-online.com

Publicité

Table des Matières
loading

Table des Matières