The spark arrestor must be cleaned or replaced every 50
hours or yearly to ensure proper performance of your prod-
uct. Spark arrestors may be in different locations depending
on the model purchased. Please contact your nearest service
dealer for the location of the spark arrestor for your model.
To clean the spark arrestor:
 Loosen the screws on the rear panel. Remove rear panel
and set aside.
 Remove the screw securing the spark arrestor in place.
 Remove the spark arrestor and gently clean using a wire
brush.
 Replace the spark arrestor and rear panel. Ensure that
all screws are tightened securely.
DRAINING FUEL TANK/CARBURETOR
See Figures 15 - 16.
To help prevent gum deposits in the fuel system, drain the
fuel from the tank and carburetor before storing.
DRAINING THE FUEL TANK:
NOTICE:
Remove all lubricant from the unit before draining the fuel
tank. Failure to do so could cause damage to the unit.
 Remove the fuel cap.
STORAGE
When preparing the generator for storage, allow the unit to cool completely then follow the guidelines below.
STORAGE TIME
Less than 2 months  Drain gasoline from tank and dispose of in a suitable container according to state and local
2 months to 1 year
 Drain fuel from carburetor.
 Drain gasoline from tank and dispose of in a suitable container according to state and local
1 year or more
 Drain fuel from the carburetor.
 Remove spark plug.
 Drain gasoline from tank and dispose of in a suitable container according to state and local
 Put a tablespoon of engine lubricant into the spark plug cylinder. Turn the engine slowly with the
 Reinstall spark plug.
 Change engine lubricant.
NOTE: If storing gasoline in suitable container for later use, make sure gasoline has been treated with fuel stabilizer
according to stabilizer manufacturer's instructions.
All manuals and user guides at all-guides.com
MAINTENANCE
ordinances.
ordinances.
ordinances.
pull rope to distribute the lubricant.
 Tilt the generator and allow fuel to drain from the fuel tank
into an approved container.
 When the fuel has drained from the tank, replace the fuel cap.
DRAINING THE CARBURETOR:
 Loosen the screws at the top of the engine cover. Remove
cover and set aside.
 Place the engine choke lever in the run position.
 Position a suitable container under the carburetor drain
screw to catch fuel; loosen the screw.
 Allow fuel to drain completely into container.
 Retighten drain screw securely.
 Place the engine choke lever in the off position.
NOTE: Consult hazardous waste management guidelines
in your area for the proper way to dispose of used fuel.
TRANSPORTING
 Place the engine choke lever in the off position.
 Make sure engine and exhaust of unit is cool.
 Keep unit level to prevent fuel spillage.
 Do not drop or strike unit or place under heavy objects.
 If transporting in a vehicle, drain the fuel tank, close the
fuel valve and securely restrain the generator.
 Provide a plastic sheet or absorbent pad below the
generator to catch any drips of fuel or lubricant.
PRIOR TO STORING