After Use; Maintenance Schedule - Nilfisk BA 500 Mode D'emploi

Table des Matières

Publicité

After Use

1
Turn the Master Key Switch (12) OFF and remove the key.
2
Step DOWN and slide the Brush Raise/Lower Pedal (14) to the right to raise the brush.
3
Raise the squeegee.
4
To empty the Solution Tank, remove the Solution Drain Hose (13) from its hanger. Direct the hose to a floor drain or bucket and remove
the plug. Draining the solution tank automatically cleans the in-line solution filter. Park the machine over a floor drain then put clean water
in the tank and hold the Solution Switch (11) in the Momentarily ON position. This will run water through the solution system and clean
out the solution valve. Inspect the solution hoses and replace if kinked or damaged.
5
To empty the Recovery Tank, remove the Recovery Drain Hose (19) from its hanger. Direct the hose to a floor drain or bucket and remove
the plug. Rinse the tank with clean water. Inspect the recovery and vacuum hoses and replace if kinked or damaged.
6
Remove the brush or pad holder. Rinse the brush or pad with warm water and hang it up to dry. Allow buffing pads to dry completely
before using again.
7
Remove the squeegee, rinse it with warm water and hang it up to dry.
8
Check the maintenance schedule below and perform any required maintenance before storage.

Maintenance Schedule

Clean and Inspect the Tanks and Hoses
*Vacuum Motor Carbon Brushes
*Have Nilfisk check the carbon motor brushes once a year or after 300 operating hours.
9
Store the machine in a clean, dry place.
23
Maintenance Item
Clean the Brushes/Pads
Clean the Squeegee
Charge the Batteries
Check Battery Water Level
Lubrication
Once a
Once a
Daily
Week
Month
X
X
X
X
X
Once a
Year
X
X

Publicité