HC150 / HC101
Solenoid driven dosing pump

3 PROGRAMMING THE PUMPS

3.1 HC150 / HC101 costant

Programming the HC150 / HC101 costant pump or in constant mode is based on the setting, using the knob,
regulating the number of pulses per minute that the pump must carry out.
It is possible to regulate the number of pulses per minute, and therefore the flow of the pump, using two regulating
scales:
Full: 0...100%
Reduced: 0...20%.

3.1.1 Scale change procedure

The following procedure allows you to switch from one scale to the other.
To perform this operation it is advisable to use a medium flat-tip screwdriver.
Turn the regulating knob to the minimum 0% (fully rotated counter clockwise):
The frequency of the flashing LED (green) indicates the scale that is currently in use:
Turn the regulating knob to the maximum position (fully rotated clockwise) immediately followed by (within
2 seconds) bringing the timer back to the minimum position.
The frequency of the flashing LED has now been changed to indicate the change in regulating scale,
repeat again if necessary.

3.1.2 Meaning of two-colour LED

Colour of the
LED
Green
Green
Red
Red
ADSP9500090
quick flashing: 0...100%
2 seconds
Status of the
LED
Flashing
Flashing
Steady
Flashing
slow flashing: 0...20%.
Position of the
regulating knob
Different from 0%
0%
Different from 0%
Different from 0%
Rev.2.5 09.09.2015
PROGRAMMING THE PUMPS
Operating status of the
pump
ON – injection with each
flash of the LED
OFF – Signals the scale
Quick flashing: 0...100%
Slow flashing: 0...20%.
OFF – level alarm
OFF – temperature alarm
ENGLISH
28