OPERATION
2. Disengage squeegee lift lever from the up position
and lower squeegee (Figure 15).
3. Turn main switch to the on position.
4. Turn brush switch to the on position to lower scrub
head to the floor (Figure 16).
5. Turn vacuum switch to the on position.
NOTE: The brushes and solution flow will not start
until control grips are rotated.
6. Before starting, turn speed control knob to slowest
setting (Figure 17).
7. Begin scrubbing by rotating control grips forward.
Gradually increase your speed by turning speed
control knob forward (Figure 17).
12
FIG. 15
FIG. 16
FIG. 17
Home Find... Go To..
8. Once machine begins to move, check the needle
position of the brush pressure meter. Use the (2)
pressure adjustment switches to adjust brush
pressure. Never operate machine in the red zone
(Figure 18).
FIG. 18
ATTENTION: To prevent floor damage and brush
motor overload, do not operate brush pressure
meter in red zone.
9. To operate machine in reverse, simply pull reverse
switch backwards (one speed)
(Figure 19).
FIG. 19
10. To stop machine, release control grips.
Speed Scrub 2401/2601 (04- -05)