18 START UP AFTER LONG STORAGE PERIODS
IF
THE
COMPRESSOR
SWITCHED OFF FOR MORE THEN TWO
MONTHS,
PLEASE
FOLLOWS :
kW 11 - 15
a) reach the intake valve (A) by: detaching
cover (B) and removing the air intake
filter cartridge (C)
b) put in 100 cc of proper oil
c) run compressor for ten seconds
d) repeat stage b an other time
replace the parts, and start unit.
e)
kW 18,5
a
reach the intake valve (A) by: detaching
cover (C) and removing the air intake
filter cartridge (B)
b
put in 100 cc of proper oil
c
run compressor for ten seconds
d
repeat stage b an other time
e
replace the parts, and start unit.

19 STARTING AT LOW TEMPERATURES

Warning: if the room temperature may fall below 0°C it is essential to protect all pipe/hosework and
condensate drains with suitable insulation. This will prevent blockage due to ice, which can cause
dangerous damages to the air reservoir.
If the room temperature remains constant around 0°C it is recommended to use a synthetic oil as
the one indicated on the table.
Recommended procedure for start-up with cold temperature (below 0 °C):
a
Start the motor up for 5 seconds then switch off before the pressure rises.
b
Repeat phase a.
c
Temporarily start the compressor, checking that the pressure rises to a value close to the
maximum working pressure
for example:
d
Switch off the compressor immediately when pressure at phase c is reached.
e
Repeat phases c - d.
f
Finally, start the compressor, making sure that the pressure is not exceeded due to the formation
of ice in the hoses and/or icing up of the retaining valve.
REMAIN
PROCEED
AS
7 BAR for 8 BAR working pressure models
9 BAR for 10 BAR working pressure models
12 BAR for 13 BAR working pressure models
2-16