Humidity Control; Control Panel; Fan Speed - Aircare 5D6700 Guide D'utilisation Et D'entretien

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

IMPORTANT: Water damage
may result if condensation
starts to form on windows or
walls. Humidity SET point
should be lowered until
condensation no longer forms.
We recommend room humidity
levels do not exceed 50%.
*Model 1990 digital hygrometer is available for purchase by calling 1-800-547-3888.
NOTE: External hygrometer readings and humidistat readings may differ. Humidity
levels can vary significantly even in one room.
OPERATION
Plug cord into wall receptacle. Your humidifier is now ready for use. The humidifier should be
placed at least FOUR inches away from any walls and away from heat registers. Unrestricted
airflow into the unit will result in the best efficiency and performance.
NOTE: This unit has an automatic humidistat located on the cord that senses the
humidity level around the immediate area of the humidifier. It turns the humidifier
on when the relative humidity in your home is below the humidistat setting and will
turn the humidifier off when the relative humidity reaches the humidistat setting.
DIGITAL DISPLAY
PRESS TO
INCREASE
HUMIDITY

HUMIDITY CONTROL

3) The hygrometer on the cord reads the current room humidity and displays the
percentage on LCD panel.
4) To set the desired humidity, press the HUMIDITY button. Each successive push
increases the humidity in 5% increments. The range is 25% to 65%.
5) At 65% the humidifier will run constantly with or without water.
NOTE: If excessive condensation occurs, reduce fan to a lower speed setting
CAUTION: Disconnect power before filling, cleaning or servicing unit. Keep
grille dry at all times.
CHECK FILTER
The ability of any humidifier to efficiently supply humidity output relies heavily on
the condition of the filter. As the filter loads with impurities it gradually loses its
wicking capability. When this happens, moisture output is reduced and the
humidifier has to work longer to satisfy the selected setting.
When Outdoor
Temperature is:
°F
-20
-10°
10°
20°
30°

CONTROL PANEL

TO TURN ON/OFF
For initial operation, plug the unit in
(the display will show - -). Press the
speed button and hold for 5 seconds
to turn the unit on or off.

FAN SPEED

The 5D6700 has a four speed digital
control panel.
1) Press the SPEED button to adjust
PRESS AND HOLD
the fan speeds.
TO TURN UNIT ON
2) The speeds: High (F4) - Low (F1)
PUSH TO ADJUST
FAN SPEED
display on the digital panel
5
Recommended
Indoor Relative
° C
Humidity (RH) is
-30°
15 - 20%
-24°
20 - 25%
-18°
25 - 30%
-12°
30 - 35%
-6°
35 - 40%
-1°
40 - 45%

Publicité

Table des Matières
loading

Table des Matières