DIGITAL DISPLAY

Press the power button once to turn the unit on. Initially there is a slight delay while the
electronics calibrate. Two bars (- -) appear during this time. Once calibration is
complete a ROOM humidity reading between 20% - 95% will be displayed. A flashing
20 display indicates that the room humidity is less than 20%.
NOTE: The default settings at initial startup are (Ultra Quiet) F1 fan speed and
65% SET humidity. After desired settings are selected by the user, they remain
as long as the unit remains plugged in and there is no power interruption. If the
unit is unplugged the original default settings are employed.
ABOUT HUMIDITY
Where you set your desired humidity levels depends on your personal comfort
level, outside temperature and inside temperature. A starting set point of 30% -
40% ROOM humidity is recommended but there may be conditions that require a
different setting.
NOTE: Recent CDC tests show that the chances of flu transmission are greatly
reduced at levels of 43% humidity. You may wish to purchase a hygrometer* to
measure the humidity level in your home. The following is a chart of
recommended humidity settings
IMPORTANT: Water
damage may result if
condensation starts to form
on windows or walls.
Humidity SET point should
be lowered until
condensation no longer
forms. We recommend
room humidity levels do not
exceed 50%.
*Model 1990 digital hygrometer is available for purchase by calling 1-800-547-3888
NOTE: External hygrometer readings and humidistat readings may differ.
Humidity levels can vary significantly even in one room. The amount of time it
takes to affect the room humidity depends on the relative humidity of the air. In
especially dry areas it could take up to 48 hours to see humidity climb to the
desired level.

HUMIDITY CONTROL

drops 3% below the relative humidity, the humidifier cycles on and off as required
to maintain the selected setting allows you to adjust the humidity to suit your
needs. The readout displays both actual (ROOM) and desired (SET) humidity
percentage (%) settings when humidity control button is pressed. The ROOM
readout has a range of 20% to 95%. If the room humidity level is equal to or less
than 20% the display will show a flashing 20.
When Outdoor
Temperature is:
°F
° C
-20
-30°
-10°
-24°
-18°
10°
-12°
20°
-6°
30°
-1°
NOTE: Allow 10 to 15 minutes for the
humidistat to adjust to the room when
setting up the unit for the first time.
The MA1201(CN) has an automatic
humidistat located on the cord that
measures the relative humidity in the
room. When the selected humidity level
6
Recommended
Indoor Relative
Humidity (RH) is
15 - 20%
20 - 25%
25 - 30%
30 - 35%
35 - 40%
40 - 45%
.

Publicité