Aircare 5D6700 Guide D'utilisation Et D'entretien page 6

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

1) This humidifier has a check filter reminder timed to appear after
720 hours of operation. When the Check Filter (CF) message is
displayed, disconnect the power cord and check the condition of
the filter. If a build-up of deposits or severe discoloration is
evident replace the filter to restore maximum efficiency.
2) The CF function is reset after plugging the unit back in.
CONTROL LOCK FEATURE
To avoid unwanted tampering with the humidifier settings the controls
can be locked.
ACTIVATION PROCEDURE
Control Lock
After the humidifier functions have been set up, hold the Speed and
Display
Humidity buttons down for 5 seconds. The display will show "CL" for
2 seconds.
Release the buttons and the control will resume the display of the room humidity.
The humidifier will continue to function with the locked in settings. If buttons are
operated while "CL" is active, the "CL" is displayed and settings are unaffected.
DEACTIVATION PROCEDURE
To deactivate the "CL" function simply press and hold both buttons for 5 seconds.
"CL" will flash at the rate of 1 second on and 1 second off for a period of 2
seconds and then resume the display of room humidity.
REPLACEMENT OF WICK
CAUTION: Before changing wick, ensure unit is turned OFF and unplugged.
NOTE: This unit uses 2 model 1040 wicks. Replace the wick at the beginning of
each season, and more often in areas with hard water.
1) Lift off chassis and set aside.
2) Lift off transition molding tray, then remove and discard used wicks.
3) Install new wicks according to instructions listed in ASSEMBLY section.
OPTIONAL AIRCARE
This humidifier is built to accommodate the two-stage 1050 optional air purifying
filter. The first stage is a high-efficiency, electrostatically-charged filter media which
traps dust, pollen and airborne pollutants. The second stage is an activated carbon
media which absorbs odors from cooking, pets or tobacco smoke.
We recommend replacing the AIRCARE
necessary. When the white filter media is coated with a layer of dust and dirt, it is
time to replace the filter.
NOTE: The certified water output of your humidifier will be reduced when using the
®
AIRCARE
filter. The AIRCARE
normal operation of the humidifier
layer of dust and dirt, it is time to replace the filter.
INSTALLATION
1) To install the optional air filter,
remove the chassis (top portion of
the unit).
2) From the rear, locate the air filter
compartment and unlatch the door.
3) Place the 1050 AIRCARE
into the compartment and close the
door.
4) Replace the chassis onto the
cabinet.
®
FILTER
®
filters are optional and are not required for
.
When the white filter media is coated with a
®
air filter
®
filter at least once a year, more often if
Unlatch and Open
Filter Compartment
Door
6
Check Filter
Function Display
Lift Top of Unit
Away from Base
Slide 1050
Air Filter into
Compartment

Publicité

Table des Matières
loading