4.3
Maximum Value Panel Meter
As a rule, the instrument always displays the maximum measurement value . Current and mini-
mum measurement values are read as follows:
Display
Max. Measurement Value
Current Measurement Value
Min. Measurement Value
Delete Max. Measurement Value (re-enable) first press ⇑ and then press ⇑ and ⇓ simultaneously
4.4
Resetting Min. and Max. Display Values
Press keys ⇑ and ⇓ simultaneously.
4.5
Min-Max Storage
The instrument always displays the current measurement value. Minimum and maximum measure-
ment values are stored as follows:
Display
Current Measurement Value
Min. Measurement Value
Max. Measurement Value
Delete Min. or Max. Measurement Value
(re-enable)
Return to Current Measurement Value
4.6
Panel Meter with Automatic Tare
With this model the first measured value is stored. The measuring instrument determines the differ-
ence between the current measurement value and the stored value (tare value) for each subsequent
measurement. The difference between these values is displayed. The right decimal point lights up.
Display
Current Differential Value
Store Tare Value
Delete Tare Value
The tare value is deleted after display storage is ended (pins 9 and 11 chap. 3.5 page 7). The right
decimal point is no longer lit up if no tare value is in storage.
4.7
Switching Hysteresis and Delay Time (Option)
The measuring instrument can be programmed with either a switching hysteresis or a delay time for
the alarm message or the relays. Switching hysteresis can be adjusted from ± 1 D to ± 127 D. A
delay between 0 and 127 s can be selected. Instructions for programming can be found in chap. 5.7
page 19.
10
Key Sequence
press P continuously
Key Sequence
press ⇑ or ⇓ and then press ⇑ and ⇓ simultaneously
P (at each level)
Key Sequence
P
press ⇑ and ⇓ simultaneously