Camille Bauer Digem f 96x48CK Mode D'emploi page 117

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Protection
Housing Front
Connections
EMC
Interference Immunity
Interference Emission
Max. Allowable Voltage
to Earth
DC Voltage Module
AC Voltage Module 100/700V
DC/AC Current Module
Temp./Pressure Modules
Frequency/R.P.M. Modules
Ambient Conditions
Operating Temperature
Storage Temperature
Relative Atmospheric Humidity
Applications Class
Vibration Resistance
Housing
Design
Front Panel Dimensions
Switch Panel Opening
Front Frame Height
Front Frame Color
Installation Depth
Weight
Connection Type
Fastening
GOSSEN-METRAWATT
EN 60529/ VDE 0470-1
IP40
IP00
EN 50082-2
EN 50081-2
300 V
1000 V
300 V
50 V
90 ... 300 V
0 ... 50 ˚C
– 20 ... 70 ˚C
max. 85 %
DIN 40040: KWG
IEC 1010-1/ EN 61010-1: 3.94
Metal Half-Shells
96 x 48 mm
+0.8
+0.6
45
x 92
mm
5 mm
black,
optionally gray, light gray, pebble gray or dark beige
max. 140 mm
approx. 500 gr.
screw terminal blocks
DIN screw clips
27