Les langues disponibles

Gas Pressure Regulator
The gas pressure regulator supplied with this range must be used.
The inlet pressure to the regulator should be as follows for proper
operation:
Natural gas:
Minimum pressure: 6" WCP
Maximum pressure: 14" WCP
LP gas:
Minimum pressure: 11" WCP
Maximum pressure: 14" WCP
Contact local gas supplier if you are not sure about the inlet
pressure.
Burner Input Requirements
Input ratings shown on the model/serial/rating plate are for
elevations up to 2,000 ft (609.6 m).
For elevations above 2,000 ft (609.6 m), ratings are reduced at a
rate of 4% for each 1,000 ft (304.8 m) above sea level (not
applicable for Canada).
Gas Supply Pressure Testing
Gas supply pressure for testing regulator must be at least
1" water column pressure above the manifold pressure shown on
the model/serial/rating plate.
Line pressure testing above ½ psi gauge (14" WCP)
The range and its individual shutoff valve must be disconnected
from the gas supply piping system during any pressure testing of
that system at test pressures in excess of ½ psi (3.5 kPa).
Line pressure testing at ½ psi gauge (14" WCP) or lower
The range must be isolated from the gas supply piping system by
closing its individual manual shutoff valve during any pressure
testing of the gas supply piping system at test pressures equal to
or less than ½ psi (3.5 kPa).
To Convert Gas Pressure Regulator
NOTE: Ranges are set for Natural gas from the factory. If you are
using the same type of gas before and after the conversion, the
gas pressure regulator does not need to be converted. Go to the
"To Convert Surface Burners" section.
For Gas Models IGL730C, WEG730H, WEG760H, MGS8880D,
KSGG700E, KSGB900E, and JGS1450D
1. Remove the premium storage drawer, warming drawer or
baking drawer.
2. Locate gas pressure regulator at rear of the drawer
compartment.
NOTE: On models with a warming drawer or baking drawer, an
access cover must be removed to access the gas pressure
regulator.
A
A. Gas pressure regulator
IMPORTANT: Do not remove the gas pressure regulator.
4
3. Remove plastic cover from gas pressure regulator cap.
4. Turn gas pressure regulator cap counterclockwise with a ⁵⁄₈"
combination wrench to remove.
NOTE: Do not remove the spring beneath the cap.
A
B
C
A. Plastic cover
B. Gas pressure regulator cap with solid end facing out
C. Gas pressure regulator cap with hollow end facing out
D. Washer
E. Gas pressure regulator cap
5. Turn over the gas pressure regulator cap and reinstall on
regulator so that the hollow end faces out and the marking
"
LP" is facing the direction shown in the above drawing.
6. Replace plastic cover over gas pressure regulator cap.
For Dual Fuel Models KSDB900E, JDS1450D, KSDG950E, and
JDS1750E
1. Move the range out approximately 1 ft (30.5 cm) from the wall.
2. Locate the gas pressure regulator at the lower right corner on
the back of the range.
A. Gas pressure regulator
IMPORTANT: Do not remove the gas pressure regulator.
3. Unscrew the metal cover and unscrew the blue regulator cap.
Keep the washer in place.
A
A. Metal cover
B. Washer
C. Blue regulator cap
Side view for Natural Gas
D
E
Side view for LP Gas
A
A
B
C