Technical Data

9.1

General Data

Supply voltage:
Power consumption:
Protection of metering unit/control unit:
Protection class:
Superposed fuse:
Operating voltage:
Internal fuse protection:
Water connection:
Water supply temperature:
Flow pressure::
Metering capacity:
Concentration setting:
Metering tolerance:
Backflow preventer:
Mounting dimensions:
Weight:
Due to the company's policy of continuous improvements to its products, the
NOTE
specifications may be changed without notice!
417101158_DG1.docx
AC 230 V
15 W
IP 24 / IP 65
II according to EN 60335-1
max. 16 A
AC 24 V
Microfuse 5 x 20, 630 mA, slow blow
Conical coupling NW 10 (for copper pipe, D. 10x1 )
max. 30°C
min. 0.16 MPa (1.6 bar) - max. 0.7 MPa (7 bar)
approx. 850 l/h (dilution for normal operation)
White eccentric: 0.25 % - 1 %, Blue eccentric: 1.5 % - 3 %
Max. + 6 %
DIN EN 1717 (Typ DB)
Width = 500 mm (with bracket), High =425 mm, Depth=200 mm
13,5 kg