Troubleshooting

Each time you stop the unit and/or take corrective action to eliminate a fault, make sure to
NOTE
reset the unit by pressing the ON/OFF (I/0) switch.
Failure
Control unit does not
work (no LED lights up,
pressing a button has no
effect)
Pressing the ON/OFF (I/0)
switch does not start the
unit; fault indicator is
flashing
Fault indicator
permanently ON
Unit switched OFF; swivel
drain outlet leaks
Concentration does not
reach the set value
Product shortage
monitoring device does
not switch the unit off
when the product
container is empty
Unit cannot be reset
417101158_DG1.docx
Cause
No supply voltage available
Fuse of control unit defective
Control PCB defective
Thermal fuse of power transformer
blown
Power transformer defective
Disinfectant container empty
Suction pipe soiled, suction pipe
defective
Connecting cable of suction pipe
defective
Metering pump leaks or defective
Suction and metering line:
Hose clamps leak; hose defective;
angled valve closed
Water flow pressure < 0.16 MPa bar
(1.6 bar)
Strainer clogged
Flow limiter encrusted with lime or
clogged
Hydraulic motor leaks
Hydraulic motor blocked
Coil of solenoid valve defective
Solenoid valve soiled or defective
Metering pump:
Suction and pressure valves soiled or
defective
Suction pipe:
Bottom valve soiled or defective
Water feed pipe soiled
Hydraulic motor defective
Suction pipe electrodes soiled or
defective, connecting cable damaged
Control PCB defective
42

Corrective Action

Restore power supply
Replace fuse
Replace control PCB
Let metering unit cool down
Replace power transformer
Connect new supply container
Clean bottom valve of suction pipe
Replace suction pipe
Replace metering pump
Tighten hose clamps, replace hose, if
necessary open angled valve
Ensure that water flow pressure is >
0.16 MPa (1.6 bar)
Clean strainer, replace it, if necessary
Clean flow limiter, replace it, if
necessary
Replace axial face seal
Replace hydraulic motor
Replace coil
Clean solenoid valve, replace
defective parts
Clean valves, replace, if necessary
Clean bottom valve, replace, if
necessary
Clean strainers in valve and in fresh
water supply pipe, replace, if
necessary
Replace hydraulic motor
Replace suction pipe
Replace control PCB
Rev. 07-01.16