Settings and Start-Up

6.1

Start-Up

NOTE
All item numbers in this section refer to the exploded view unless otherwise stated.
If products are used which contain glucoprotamine (e.g. INCIDIN PLUS), the O-rings on
ATTENTION
the piston and on the piston rod need to be replaced by EPDM O-rings.
After connection and installation work proceed as follows:
 Open the angled valve (G ½) to its full open position, and check it for tightness.
 Connect the disinfectant supply container as follows:
 swivel suction pipe to front position and insert it into opening of supply container,
 place the supply container onto the bracket.
Bleed the metering pump as follows:
 unscrew the flow control device (see Fig. 3.2, pos. 18)
(black coupling nut) and place it in a suitable jar,
 Close the opening of the mixing chamber (see Fig. 3.2, pos. 16) by inserting the
sealing plug (see Fig. 3.2, pos. 15),
 unscrew the knurled nut (see Fig. 6.1, pos. 3) and withdraw the eccentric
(see Fig. 6.1, pos. 1) from its holder located on the hydraulic motor
(see Fig. 6.1, pos. 6),
 move the connecting rod including the piston rod (see Fig. 6.1, pos. 7) forth and
back until disinfectant runs out from the flow control device and no more bubbles
are visible in the hoses,
 remove the sealing plug and screw in the flow control device again with the VA
pins pointing downwards,
 plug in the eccentric back in and tighten the knurled nut.
Set the desired concentration as described in chapter
and check it as described in chapter
Check the safety equipment as described in chapter
Equipment".
Check all lines and components which come in contact with water and/or disinfectant
for tightness.