4. Center bricks are installed towards the center of the broiler in three rows of four bricks each.
Install the center bricks similar to that of the side bricks in Step 3. Angle the bricks and slip them
up between the burners, then set them in place.
The center bricks are to be installed to rest between two burners on the vertical burner flange
NOTE:
(Fig. 13 and 14).
LEVELING AND CONNECTING MANIFOLDS - ALL MODELS
The IR2 Model is not designed to be batteried to other heavy duty equipment. After leveling the IR2
Model, as described in Step 2, proceed to Gas Connections.
1. Place the broiler in its exact position or battery lineup.
2. Using a carpenter level, level the broiler from front to rear and from side to side. Unless the
broilers are level, they will not give proper cooking results, and equipment being batteried will
not draw up tight.
As of January 1998, Vulcan-Hart appliances use Ward gas unions instead of Stockham gas unions.
If you are installing a new battery range to an existing field appliance, the union on the existing field
appliance must be checked against the union being used on the new range. The union manufacturer's
name around the face surface of the union nut must match. The new range has been shipped with a
Ward union. If the old appliance has something different, i.e., Stockham, it must be replaced with a
Ward union. Failure to replace this union could result in a gas leak (Fig. 15).
If a Ward gas union is needed for installation, purchasing information may be obtained through the
Vulcan-Hart Parts Department.