MAINTENANCE AND INSPECTION
Read section titled "SAFETY" (pages 4 – 8).
● Disconnect air hose and remove all nails
from Nailer when:
1) doing maintenance and inspection; and
2) clearing a jam.
● Never use gasoline or other highly fl ammable
liquides for cleaning.
1. Clearing a jam
Remove a jammed nail in the following order:
1 DISCONNECT AIR HOSE.
2 Open the nail guide.
3 Insert a rod into the outlet.
Tap the rod with a hammer.
4 Remove the jammed nail with a slotted screw
driver.
Nail
18
MAINTENANCE
WARNING
Hammer
Rod
Outlet
Disconnect
1
air hose
Slotted Screw Driver
5 Cut the deformed collated wire with nippers.
Correct the deformation.
6 In case of frequent jam, contact a Hitachi
authorized service center.
2. Inspecting the push lever
1 DISCONNECT AIR HOSE.
2 Clean the push lever sliding part.
Lubricate it with Hitachi pneumatic tool lubricant.
Lubricate
3. Inspecting the feeders
1 DISCONNECT AIR HOSE.
2 Clean the knob sliding part.
Lubricate it with Hitachi pneumatic tool lubricant.
Nail Guide
3 Open the nail guide and remove dust.
Lubricate the nose opening and feeder shaft.
CAUTION
● Check that the main nail stopper and sub nail
stopper slide smoothly by pushing them with
fi nger.
If not smooth, nails can be driven at an irregular
angle and hurt someone.
Disconnect