2 If nails are driven too deep, turn the adjuster
counterclockwise while pulling it downward.
When the adjuster is released, it returns upward.
Furthermore, turn the adjuster until it reaches a
position where it gets fi xed with a clock.
Turn Adjuster
Too Deep
2
If nails are driven too shallow, turn the adjuster
clockwise while pulling it downward.
When the adjuster is released, it return upward.
Furthermore, turn the adjuster until it reaches a
position where it gets fi xed with a clock.
Turn Adjuster
Too Shallow
2
The adjuster can be fi exed each at 1/4 rotation.
The adjuster moves approximately 0.25 mm per 1/4
rotation.
3 Stop turning the adjuster when a suitable position is
reached for a nailing test.
4 Connect the air hose.
ALWAYS WEAR EYE PROTECTIOR.
Perform a nailing test.
5 DISCONNECT AIR HOSE FROM NAILER.
6 Choose a suitable position for the adjuster.
Flush
Flush